KTN certifications
PED Module H certificate: valves manufactured to Directive 2014/68/EU
KTN manages the design, manufacture and inspection of its valves under a quality system approved by Bureau Veritas according to Module H of the Pressure Equipment Directive 2014/68/EU. Certificate CE-0056-PED-H-KTN 001-26-ESP covers design, manufacture, final inspection and testing. It is valid until 20 April 2029.

NumberCE-0056-PED-H-KTN 001-26-ESP
Notified bodyBureau Veritas, no. 0056
Valid until20 April 2029
Certificate details
PED Module H certificate
| Number | CE-0056-PED-H-KTN 001-26-ESP |
| Directive | 2014/68/EU Pressure Equipment Directive (PED), Annex III, Module H |
| Notified body | Bureau Veritas Inspección y Testing, S.L.U., no. 0056 |
| ENAC accreditation of the body | 49/C-SG089 |
| Holder | Kara Technology News, S.L. (KTN brand) |
| Address | Ctra. Rubí a Sabadell, km 13, nave 7, 08191 Rubí (Barcelona), Spain |
| Equipment | Pressure accessories: valves |
| Scope | Design, manufacture, final product inspection and testing |
| Last audit | 10 December 2025 |
| Issue date | 21 April 2026 |
| Valid until | 20 April 2029 |
| Registration code | 2026/000100/CE-0056-PED |
Download PDF
PDF · 9 pages · 0.9 MB · in Spanish
Audit scope
What Bureau Veritas certifies at KTN
Bureau Veritas has audited the quality system KTN applies to every valve, from start to finish. The audit covers four stages:
Design
Calculation and specification of bodies, closure members and seats according to the essential safety requirements of the directive.
Manufacture
Machining, assembly and materials control.
Final product inspection
Each valve is checked before it leaves the factory.
Testing
Pressure and leak-tightness tests.
The certificate is not granted once and then forgotten. Bureau Veritas carries out surveillance audits, visits and tests throughout its validity. If KTN stopped complying with the directive, the certificate would no longer be valid.
The directive
What is the Pressure Equipment Directive (PED)?
Directive 2014/68/EU, known as the PED (Pressure Equipment Directive), governs the design, manufacture and conformity assessment of equipment with a maximum allowable pressure above 0.5 bar. It replaced Directive 97/23/EC and is transposed in Spain by Royal Decree 709/2015.
The directive classifies valves as pressure accessories. Each valve falls into a risk category, from I to IV, based on three factors:
- Nominal size (DN).
- Maximum allowable pressure (PS).
- Fluid group. Group 1 for dangerous fluids (flammable, toxic, oxidising) and group 2 for all others, such as water, air or steam.
Valves below the category I thresholds fall under Article 4(3). They are manufactured according to sound engineering practice and do not carry CE marking.
Assessment procedure
What Module H is and how it differs from other modules
The directive sets out which assessment procedures, called modules, the manufacturer may use for each category.
A manufacturer may apply the module of a higher category. That is why Module H is valid for categories I, II and III. KTN does not manufacture category IV valves, so Module H covers its entire range subject to the directive.
Module H is known as «full quality assurance». In other modules the body examines a valve type or verifies specific batches. Under Module H it approves and monitors the whole system, including design. Any valve manufactured within that system is covered, with no need to wait for an external inspection on each order.
| PED category | Permitted modules |
|---|---|
| I | A |
| II | A2, D1, E1 |
| III | B + D, B + F, B + E, B + C2, H |
| IV | B + D, B + F, G, H1 |
For buyers
What it means for you as a buyer
The certificate translates into five specific guarantees for your installation:
- CE marking with number 0056. Valves subject to a PED category carry the CE marking on the nameplate, followed by the Bureau Veritas number.
- EU declaration of conformity. KTN sends it in digital format with every order of CE-marked equipment.
- Independent third-party control. A body notified by the Spanish Ministry of Industry and accredited by ENAC reviews the system periodically.
- Traceability. Certificate of origin with every order and 3.1 material certificate on request.
- PED conformity. CE marking certifies conformity with the PED, without prejudice to the requirements applicable to installation and service.
This is the documentation the inspector or control body asks for when approving a pressure installation.
Certificate annex
Which valves it covers
The certificate annex includes five valve families, in PED categories I, II and III, suitable for group 1 fluids (dangerous fluids: flammable, toxic or oxidising).
Swipe the table to see all columns →
| Family | DIN version | ANSI version | Temperature | Materials |
|---|---|---|---|---|
| Ball valves | DN15 to DN400, PN10 to PN250 | 1¼″ to 12″ (DN32 to DN300), Class 150 to 2500 | −29 to 180 °C | Carbon and stainless steel |
| Butterfly valves | DN40 to DN500, PN10 and PN16 | Not included | −35 to 155 °C | Ductile iron and stainless steel |
| Gate valves | DN50 to DN300, PN16 to PN100 | 1¼″ to 20″ (DN32 to DN500), Class 150 to 2500 | −29 to 425 °C | Carbon and stainless steel |
| Globe valves | DN32 to DN250, PN16 to PN130 | 1¼″ to 20″ (DN32 to DN500), Class 150 to 2500 | −29 to 425 °C | Carbon and stainless steel |
| Check valves | DN32 to DN400, PN10 to PN130 | 1¼″ to 20″ (DN32 to DN500), Class 150 to 800 | −29 to 425 °C | Carbon and stainless steel |
The ranges are the limits stated in the annex: each series has its own size, pressure and temperature limits, shown in the full certificate and in every quotation. Control valves are not included in the annex.
Small-bore valves may fall under Article 4(3) of the directive. In that case they do not carry CE marking, although they are manufactured under the same quality system.
Authenticity
How to verify the certificate
You can check that the certificate is genuine in three steps:
Note the numbers
Certificate number CE-0056-PED-H-KTN 001-26-ESP and registration code 2026/000100/CE-0056-PED.
Scan the QR code
It is on the first page of the PDF.
Contact Bureau Veritas
Bureau Veritas Inspección y Testing (Sant Cugat del Vallès, Spain), quoting both numbers.
Number 0056 also appears in the European Commission’s NANDO database, which lists the notified bodies for Directive 2014/68/EU.
Comparison
PED and ISO 9001: two different certificates
KTN holds both, and each one guarantees something different:
Swipe the table to see all columns →
| Aspect | PED Module H | ISO 9001:2015 |
|---|---|---|
| Issued by | Bureau Veritas, notified body 0056 | SGS |
| Nature | Mandatory for CE marking of pressure equipment | Voluntary |
| What it assesses | Design, manufacture, inspection and testing of valves under the directive | Quality management system for sales and distribution |
| Allows CE marking | Yes | No |
| More information | This page | ISO 9001 certificate |
Certifications
Other KTN certifications

ISO 9001:2015
Quality management system for the sale and distribution of valves, instrumentation and industrial equipment. Valid until 14 June 2027.

ATEX technical file
Ball valves for potentially explosive gas atmospheres, marked Ex II 2G Ex h IIC T6 Gb for zones 1 and 2.
Quotation
Request your quotation with PED documentation
Tell us the DN, pressure, temperature, fluid and valve type. We will send you the quotation together with the PED certificate and the technical data sheet for the version.
Email: ktn@ktnvalves.com
Phone: +34 937 818 219
Hours: 8:00 to 19:00 (CET)
Common questions
Frequently asked questions about the PED Module H certificate
Do you need PED documentation for your project? Get in touch and we will send it with your quotation.
01. What is the PED certificate?
It is the document with which a notified body confirms that a manufacturer complies with the Pressure Equipment Directive 2014/68/EU. Without it, valves in category II or above cannot carry CE marking or be sold in the EU. KTN’s certificate is issued by Bureau Veritas, notified body 0056.
02. What does PED Module H mean?
It is the «full quality assurance» procedure. The notified body approves and monitors the manufacturer’s entire quality system: design, manufacture, final inspection and testing. It applies to equipment in categories I, II and III.
03. What does «CE 0056» on a valve nameplate mean?
CE indicates that the valve complies with the applicable European directive. Number 0056 identifies Bureau Veritas as the notified body that monitors the quality system under which it was manufactured. Every notified body in Europe has its own four-digit number.
04. Do all valves need CE marking under the PED?
No. The directive only applies above a maximum allowable pressure of 0.5 bar. In addition, valves below the category I thresholds fall under Article 4(3): they are manufactured according to sound engineering practice and must not carry CE marking.
05. How is the PED category of a valve determined?
By three factors: nominal size (DN), maximum allowable pressure (PS) and fluid group. Dangerous fluids (group 1) move a valve into a higher category sooner than water, air or steam (group 2). Send us these details and we will confirm the category of your valve.
06. Is the PED the same as ISO 9001?
No. The PED is mandatory for CE marking of pressure equipment and is issued by a notified body. ISO 9001 is a voluntary quality management standard. KTN holds both: the PED certificate from Bureau Veritas and ISO 9001:2015 from SGS.
07. How long is KTN’s PED certificate valid?
Until 20 April 2029. During that time Bureau Veritas carries out surveillance audits. The last renewal audit took place on 10 December 2025.
08. Can I request the certificate and declaration of conformity with my order?
Yes. With every order of CE-marked equipment we send the EU declaration of conformity in digital format. The full PED certificate can be downloaded from this page. Request it using the contact form, stating the valve type and DN.
09. How can I check that the certificate is genuine?
Scan the QR code on the certificate or contact Bureau Veritas quoting number CE-0056-PED-H-KTN 001-26-ESP and registration code 2026/000100/CE-0056-PED. You can also confirm number 0056 in the European Commission’s NANDO database.