KTN certifications
ATEX technical file
KTN manufactures ball valves for potentially explosive atmospheres in accordance with ATEX Directive 2014/34/EU. The technical file for these valves is deposited with the Laboratorio Oficial J. M. Madariaga, notified body 0163, under deposit number LOM 26.381X-C.

Deposit numberLOM 26.381X-C
Notified bodyLaboratorio Oficial J. M. Madariaga, no. 0163
MarkingEx II 2G Ex h IIC T6 Gb
Certificate details
Technical file deposit
| Deposit number | LOM 26.381X-C |
| Directive | 2014/34/EU (ATEX), Article 13(1)(b)(ii) |
| Notified body | Laboratorio Oficial J. M. Madariaga (LOM), no. 0163 |
| Product | Ball valves |
| Manufacturer | Kara Technology News, S.L.U. |
| Technical file | 202601/00 |
| ATEX marking | Ex II 2G Ex h IIC T6 Gb |
| Zones of use | Zones 1 and 2 (gases and vapours) |
| Deposit date | 23 June 2026 |
| Held until | 22 June 2037 |
Download PDF
PDF · 1 page · 0.3 MB · in Spanish
The directive
What is ATEX Directive 2014/34/EU?
Directive 2014/34/EU governs equipment intended for use in potentially explosive atmospheres. Its name comes from the French ATmosphères EXplosibles. An explosive atmosphere forms when flammable gases, vapours, mists or dusts mix with air in proportions that can be ignited by a spark or a hot surface.
The directive sets the design and manufacturing requirements so that the equipment is not a source of ignition. It applies to industries such as chemicals, petrochemicals, refining, pharmaceuticals or gas processing.
In Spain it is transposed by Royal Decree 144/2016.
Classification
ATEX zones and equipment categories
The plant owner classifies its areas into zones according to the likelihood of an explosive atmosphere occurring. Each zone requires a minimum equipment category:
Swipe the table to see all columns →
| Zone | Explosive atmosphere | Minimum category |
|---|---|---|
| 0 | Continuously or for long periods | 1 |
| 1 | Likely in normal operation | 2 |
| 2 | Unlikely and only for short periods | 3 |
KTN ball valves are category 2G: they can be installed in zones 1 and 2 with gases and vapours, including the most demanding ones in group IIC.
Procedure
What depositing the technical file means
For category 2 non-electrical equipment, such as a ball valve, the directive sets out this procedure:
Risk analysis
The manufacturer analyses the ignition risks of the valve and applies the measures to eliminate them.
Technical file
It compiles that analysis, the calculations, drawings, materials and instructions into a technical file.
Deposit
It deposits the file with a notified body, which keeps it for at least 10 years.
Declaration and marking
The manufacturer issues the EU declaration of conformity and marks the valves with CE marking and ATEX marking.
KTN deposited its file 202601/00 with the Laboratorio Oficial J. M. Madariaga on 23 June 2026. The laboratory will hold it until 22 June 2037.
The notified body keeps the file and makes it available to the authorities on request. Conformity is declared by the manufacturer, who is responsible for it.
Safety
Which ignition risks an ATEX ball valve controls
A ball valve has no electrical components, but it can cause ignition in two ways:
Static electricity
PTFE seats insulate the ball from the body, and fluid friction can charge it. That is why the valve must be earthed in the installation. According to KTN’s EU declaration, earthing the assembly is the responsibility of whoever is in charge of the line where the valve is fitted.
Frictional heating
Surfaces must not exceed the maximum temperature set by the temperature class. For KTN valves it is T6: the surface does not exceed 85 °C.
On automated valves, the actuator and electrical accessories must carry their own ATEX marking compatible with the zone.
Marking
How to read the ATEX marking on the valve
Marking of KTN ball valves, preceded by the hexagonal Ex symbol:
Ex II 2G Ex h IIC T6 Gb
Swipe the table to see all columns →
| Part | Example | Meaning |
|---|---|---|
| Equipment group | II | Surface industries (not mining) |
| Category and atmosphere | 2G | Category 2, for gas atmospheres (G) |
| Type of protection | Ex h | Non-electrical equipment, to EN ISO 80079-36 |
| Gas group | IIC | IIC covers the most demanding gases, such as hydrogen and acetylene |
| Temperature class | T6 | Maximum surface temperature of 85 °C |
| Equipment protection level | Gb | Level equivalent to category 2 |
For buyers
What it means for you as a buyer
- Legal installation in a classified zone. The valve complies with the directive for the category shown in its marking.
- Documentation for your explosion protection document. You receive the EU declaration of conformity in digital format.
- File held by a third party. The authorities can consult it at LOM for 10 years.
- A single reference for pressure and explosion. The same ball valves are manufactured under the Bureau Veritas PED Module H certificate. The certificate annex includes DIN and ANSI ball valves up to Class 2500, suitable for group 1 fluids.
Scope
Which valves are included
The file and the EU declaration of conformity cover KTN’s entire ball valve range:
Accessories fitted to the valve (actuators, solenoid valves, limit switches) are not covered by this declaration: each must carry its own ATEX marking and declaration.
Butterfly, globe, gate, check and control valves are not included in this file. KTN is working to extend ATEX conformity to other families.
Authenticity
How to verify the deposit
Note the numbers
Number LOM 26.381X-C and file code 202601/00.
Contact LOM
The Laboratorio Oficial J. M. Madariaga (Getafe, Madrid) will confirm the deposit.
Check NANDO
Check that number 0163 appears in the European Commission’s NANDO database for Directive 2014/34/EU.
Certifications
Other KTN certifications

PED Module H certificate
Design, manufacture, final inspection and testing of our pressure valves under Directive 2014/68/EU. Valid until 20 April 2029.

ISO 9001:2015
Quality management system for the sale and distribution of valves, instrumentation and industrial equipment. Valid until 14 June 2027.
Quotation
Request a quotation for ATEX ball valves
Tell us the zone, fluid, DN, pressure and operating temperature. We will send you the quotation with the ATEX EU declaration of conformity and the technical data sheet.
Email: ktn@ktnvalves.com
Phone: +34 937 818 219
Hours: 8:00 to 19:00 (CET)
Common questions
Frequently asked questions about the ATEX technical file
Does your installation have classified zones? Tell us the zone and fluid and we will help you choose the valve.
01. What is an ATEX valve?
It is a valve designed and manufactured so that it does not ignite an explosive atmosphere, in accordance with Directive 2014/34/EU. It carries CE marking and an ATEX marking that indicates the zones where it can be installed.
02. In which zones can KTN ATEX ball valves be installed?
Their Ex II 2G Ex h IIC T6 Gb marking allows them to be installed in zones 1 and 2 with gases and vapours, including group IIC gases such as hydrogen and acetylene. They are not suitable for zone 0, which requires category 1.
03. What is the difference between a technical file deposit and an ATEX certificate?
With an EU type-examination certificate, the notified body tests the equipment. With a deposit, the manufacturer assesses conformity and deposits the technical file with the body, which keeps it. The directive provides for the deposit for category 2 non-electrical equipment, such as ball valves.
04. What does «Ex h» in the marking mean?
It identifies the protection of non-electrical equipment according to EN ISO 80079-36. It indicates that the manufacturer has analysed and eliminated the equipment’s own ignition sources, such as static electricity or frictional heat.
05. Why might a manual valve need ATEX?
Because it can cause ignition without electricity. Fluid friction charges the ball when the PTFE seats insulate it from the body, and a single discharge is enough to ignite an explosive atmosphere. An anti-static device prevents that build-up.
06. Can I automate an ATEX ball valve?
Yes, but the actuator, limit switch box and solenoid valve must carry their own ATEX marking, compatible with the zone. The assembly must meet the most demanding category of the installation. We can supply the complete assembly.
07. Are KTN butterfly or globe valves ATEX?
Not under this file. Deposit LOM 26.381X-C covers ball valves only. KTN is working to extend ATEX conformity to other families. If you need another valve type for a classified zone, contact us.
08. How long is the deposit valid?
LOM holds the file until 22 June 2037. The valves covered by this file may be placed on the market until 22 June 2027. To continue selling them after that date, the file is renewed with the notified body.
09. What documentation do I receive with the valve?
The EU declaration of conformity, in digital format. On request, the 3.1 material certificate.
10. How can I verify the file deposit?
Contact the Laboratorio Oficial J. M. Madariaga quoting number LOM 26.381X-C and file 202601/00. You can also confirm body 0163 in the European Commission’s NANDO database.