KTN certifications

ATEX technical file

KTN manufactures ball valves for potentially explosive atmospheres in accordance with ATEX Directive 2014/34/EU. The technical file for these valves is deposited with the Laboratorio Oficial J. M. Madariaga, notified body 0163, under deposit number LOM 26.381X-C.

Deposit numberLOM 26.381X-C

Notified bodyLaboratorio Oficial J. M. Madariaga, no. 0163

MarkingEx II 2G Ex h IIC T6 Gb

View full details

Certificate details

Technical file deposit

Deposit numberLOM 26.381X-C
Directive2014/34/EU (ATEX), Article 13(1)(b)(ii)
Notified bodyLaboratorio Oficial J. M. Madariaga (LOM), no. 0163
ProductBall valves
ManufacturerKara Technology News, S.L.U.
Technical file202601/00
ATEX markingEx II 2G Ex h IIC T6 Gb
Zones of useZones 1 and 2 (gases and vapours)
Deposit date23 June 2026
Held until22 June 2037
KTN ATEX technical file deposit document at LOM

Download PDF
PDF · 1 page · 0.3 MB · in Spanish

The directive

What is ATEX Directive 2014/34/EU?

Directive 2014/34/EU governs equipment intended for use in potentially explosive atmospheres. Its name comes from the French ATmosphères EXplosibles. An explosive atmosphere forms when flammable gases, vapours, mists or dusts mix with air in proportions that can be ignited by a spark or a hot surface.

The directive sets the design and manufacturing requirements so that the equipment is not a source of ignition. It applies to industries such as chemicals, petrochemicals, refining, pharmaceuticals or gas processing.

In Spain it is transposed by Royal Decree 144/2016.

Classification

ATEX zones and equipment categories

The plant owner classifies its areas into zones according to the likelihood of an explosive atmosphere occurring. Each zone requires a minimum equipment category:

Swipe the table to see all columns →

ZoneExplosive atmosphereMinimum category
0Continuously or for long periods1
1Likely in normal operation2
2Unlikely and only for short periods3

KTN ball valves are category 2G: they can be installed in zones 1 and 2 with gases and vapours, including the most demanding ones in group IIC.

Procedure

What depositing the technical file means

For category 2 non-electrical equipment, such as a ball valve, the directive sets out this procedure:

01

Risk analysis

The manufacturer analyses the ignition risks of the valve and applies the measures to eliminate them.

02

Technical file

It compiles that analysis, the calculations, drawings, materials and instructions into a technical file.

03

Deposit

It deposits the file with a notified body, which keeps it for at least 10 years.

04

Declaration and marking

The manufacturer issues the EU declaration of conformity and marks the valves with CE marking and ATEX marking.

KTN deposited its file 202601/00 with the Laboratorio Oficial J. M. Madariaga on 23 June 2026. The laboratory will hold it until 22 June 2037.

The notified body keeps the file and makes it available to the authorities on request. Conformity is declared by the manufacturer, who is responsible for it.

Safety

Which ignition risks an ATEX ball valve controls

A ball valve has no electrical components, but it can cause ignition in two ways:

01

Static electricity

PTFE seats insulate the ball from the body, and fluid friction can charge it. That is why the valve must be earthed in the installation. According to KTN’s EU declaration, earthing the assembly is the responsibility of whoever is in charge of the line where the valve is fitted.

02

Frictional heating

Surfaces must not exceed the maximum temperature set by the temperature class. For KTN valves it is T6: the surface does not exceed 85 °C.

On automated valves, the actuator and electrical accessories must carry their own ATEX marking compatible with the zone.

Marking

How to read the ATEX marking on the valve

Marking of KTN ball valves, preceded by the hexagonal Ex symbol:

Ex II 2G Ex h IIC T6 Gb

Swipe the table to see all columns →

PartExampleMeaning
Equipment groupIISurface industries (not mining)
Category and atmosphere2GCategory 2, for gas atmospheres (G)
Type of protectionEx hNon-electrical equipment, to EN ISO 80079-36
Gas groupIICIIC covers the most demanding gases, such as hydrogen and acetylene
Temperature classT6Maximum surface temperature of 85 °C
Equipment protection levelGbLevel equivalent to category 2

For buyers

What it means for you as a buyer

  • Legal installation in a classified zone. The valve complies with the directive for the category shown in its marking.
  • Documentation for your explosion protection document. You receive the EU declaration of conformity in digital format.
  • File held by a third party. The authorities can consult it at LOM for 10 years.
  • A single reference for pressure and explosion. The same ball valves are manufactured under the Bureau Veritas PED Module H certificate. The certificate annex includes DIN and ANSI ball valves up to Class 2500, suitable for group 1 fluids.

Scope

Which valves are included

The file and the EU declaration of conformity cover KTN’s entire ball valve range:

Accessories fitted to the valve (actuators, solenoid valves, limit switches) are not covered by this declaration: each must carry its own ATEX marking and declaration.

Butterfly, globe, gate, check and control valves are not included in this file. KTN is working to extend ATEX conformity to other families.

Authenticity

How to verify the deposit

01

Note the numbers

Number LOM 26.381X-C and file code 202601/00.

02

Contact LOM

The Laboratorio Oficial J. M. Madariaga (Getafe, Madrid) will confirm the deposit.

03

Check NANDO

Check that number 0163 appears in the European Commission’s NANDO database for Directive 2014/34/EU.

Certifications

Other KTN certifications

Bureau Veritas · Notified body 0056

PED Module H certificate

Design, manufacture, final inspection and testing of our pressure valves under Directive 2014/68/EU. Valid until 20 April 2029.

View PED certificate →

SGS · Certified since 2018

ISO 9001:2015

Quality management system for the sale and distribution of valves, instrumentation and industrial equipment. Valid until 14 June 2027.

View ISO 9001 certificate →

Quotation

Request a quotation for ATEX ball valves

Tell us the zone, fluid, DN, pressure and operating temperature. We will send you the quotation with the ATEX EU declaration of conformity and the technical data sheet.

Email: ktn@ktnvalves.com
Phone: +34 937 818 219
Hours: 8:00 to 19:00 (CET)

Privacy

Common questions

Frequently asked questions about the ATEX technical file

Does your installation have classified zones? Tell us the zone and fluid and we will help you choose the valve.

Request a quote

01. What is an ATEX valve?

It is a valve designed and manufactured so that it does not ignite an explosive atmosphere, in accordance with Directive 2014/34/EU. It carries CE marking and an ATEX marking that indicates the zones where it can be installed.

02. In which zones can KTN ATEX ball valves be installed?

Their Ex II 2G Ex h IIC T6 Gb marking allows them to be installed in zones 1 and 2 with gases and vapours, including group IIC gases such as hydrogen and acetylene. They are not suitable for zone 0, which requires category 1.

03. What is the difference between a technical file deposit and an ATEX certificate?

With an EU type-examination certificate, the notified body tests the equipment. With a deposit, the manufacturer assesses conformity and deposits the technical file with the body, which keeps it. The directive provides for the deposit for category 2 non-electrical equipment, such as ball valves.

04. What does «Ex h» in the marking mean?

It identifies the protection of non-electrical equipment according to EN ISO 80079-36. It indicates that the manufacturer has analysed and eliminated the equipment’s own ignition sources, such as static electricity or frictional heat.

05. Why might a manual valve need ATEX?

Because it can cause ignition without electricity. Fluid friction charges the ball when the PTFE seats insulate it from the body, and a single discharge is enough to ignite an explosive atmosphere. An anti-static device prevents that build-up.

06. Can I automate an ATEX ball valve?

Yes, but the actuator, limit switch box and solenoid valve must carry their own ATEX marking, compatible with the zone. The assembly must meet the most demanding category of the installation. We can supply the complete assembly.

07. Are KTN butterfly or globe valves ATEX?

Not under this file. Deposit LOM 26.381X-C covers ball valves only. KTN is working to extend ATEX conformity to other families. If you need another valve type for a classified zone, contact us.

08. How long is the deposit valid?

LOM holds the file until 22 June 2037. The valves covered by this file may be placed on the market until 22 June 2027. To continue selling them after that date, the file is renewed with the notified body.

09. What documentation do I receive with the valve?

The EU declaration of conformity, in digital format. On request, the 3.1 material certificate.

10. How can I verify the file deposit?

Contact the Laboratorio Oficial J. M. Madariaga quoting number LOM 26.381X-C and file 202601/00. You can also confirm body 0163 in the European Commission’s NANDO database.